Check a proposed die by hand

The initial example is mild steel, 2 mm thick, with V = 16 mm. Select material and enter thickness and actual die opening in mm. Selecting material resets V to its first starting value (10t for stainless). Thickness changes update V until you type in the V field; your edited opening is then kept until you select material again.

For a different calculation, use All sheet-metal calculators.

Teaching assumption, not a factory trial: 2 mm mild steel gives a starting V = 8 × 2 = 16 mm and a radius range of 2.0–2.5 mm. The flange rule gives 0.5 × 16 + 2 = 10 mm. A proposed 20 mm opening changes that flange estimate to 12 mm. The displayed radius remains the material/thickness rule: changing the custom V opening does not recalculate a physical radius model. Do not use that unchanged radius as proof of the radius produced by the new die.

Distinguish starting V, radius estimate and minimum flange

The recommended V opening and radius depend on material and thickness, not your edited V. Only the flange estimate uses the opening entered in the V field. The reference table has four columns: thickness, material, V opening and inside radius. It does not contain a flange column; use the live flange result or the formula below.

Rules used for each material

  • Mild steel: V opening at 8 times thickness, inside radius 1.0 to 1.25 times thickness.
  • Stainless steel: V opening at 10 to 12 times thickness, inside radius 1.5 to 2.0 times thickness.
  • Soft aluminium: V opening at 6 times thickness, inside radius about 0.8 times thickness.
  • Minimum flange: 0.5 times the V opening plus the sheet thickness.

Stainless steel is shown as two openings on purpose. The selection guidance gives a range, so the calculator returns both the 10t and the 12t value instead of inventing an 11t middle figure. Choose between them by the required radius, the available tooling and the machine tonnage.

Calculate V opening, radius and flange from the stated rules

The V opening is a multiple of thickness, with the multiple set by material: 8t for mild steel, 10t or 12t for stainless steel and 6t for soft aluminium. The inside radius range is a second material multiple applied to thickness. The minimum flange is half the chosen V opening plus thickness. Those are simple multiplications; the engineering judgement is in choosing the multiple and confirming it with the actual tooling.

For an otherwise unchanged air bend, a wider V reduces required force but changes the formed-radius and flange requirements. The displayed radius does not model that V-dependent change. A flange below the estimate calls for a tooling review, not an automatic verdict that the part cannot be made.

Check the trade-off with Recalculate force with the actual V.

For tooling geometry, see Die geometry and support.

Check material, die opening and flange assumptions

  • For coated or clad sheet, record total thickness, substrate and coating details and have engineering confirm which thickness to use.
  • The V opening is the actual die opening, measured across the V, not the die width or the machine slot spacing.
  • The inside radius is the formed radius after springback, not the punch tip radius. A punch with a small tip in a wide V die can leave a larger inside radius than the tip suggests.
  • The minimum flange rule of thumb assumes a normal air bend. A very short flange, a hemmed edge or a bend near a cut-out needs a tooling review.
  • The material categories are broad. High-strength steel, hardened stainless and tempered aluminium can need a larger V opening than the table shows.

For the bending process, see Air-bending principles.

Reference thickness rows and accepted input limits

The table lists seven thicknesses from 0.5 to 8 mm; these are reference rows, not a validated process range. Software accepts 0 < thickness ≤ 50 mm and 0 < V ≤ 500 mm. Valid inputs outside the table still use the same rules. Neither acceptance nor a table row confirms material, machine or tooling suitability.

Confirm the tool and the first part

Read the die drawing for the opening and shoulder geometry, check punch and die angles, tool load limits and part clearance, then recalculate force with the chosen V opening. The flange result is a screening rule, not a guaranteed support length or a dimensioning specification; state whether the drawing uses an outside virtual corner or a tangent length and have tooling engineering check the support geometry. After a trial, measure the unloaded included angle and inside radius, note the instrument/method and record the actual thickness, batch and tool IDs. A radius gauge comparison is an estimate unless its resolution supports the drawing tolerance.

Using the result in a quotation

Use the V opening and flange estimate to prepare a tooling review. A short flange may require another die, special tooling or a process change, affecting the quotation. Record material, thickness, selected V and radius assumptions with the price.

The inquiry button includes the entered V opening alongside the recommended opening, radius estimate and flange estimate. Keep the drawing, material condition and tool IDs with the quotation. The existing trial-record CSV contains theoretical values and user-entered, unverified measurements; changing theoretical inputs clears the measurement draft. A downloaded record is not a factory validation.

After the tooling review, continue to Press brake selection.

Confirm tooling and a trial bend before quoting

The result is an estimate for quotation preparation. Confirm the die, punch tip, inside radius and minimum flange with engineering and a trial bend before quoting or releasing a bending program.