What a general tolerance is
A general tolerance supplies limits for dimensions that have no individual tolerance indication within its stated scope. A note in the title block, drawing or contract identifies the applicable standard and class, so the same limit need not be repeated beside every dimension. Start with any individual tolerance, then check whether the general note covers the remaining dimension. Reference dimensions, theoretically exact dimensions and separately controlled features need their own interpretation.
When no general tolerance is specified in the drawing, contract or referenced documents, ask the responsible party to confirm the requirement and record the answer. Class m must be explicitly specified; it is not a fallback for an incomplete drawing.
How the class system works
GB/T 1804 uses the classes f, m, c and v, from fine to coarse. Class m applies only when explicitly specified in the drawing or contract. ISO 2768-1 concerns linear and angular dimensions without individual tolerance indications. A general reference to ISO 2768 does not establish applicability or numerical equivalence with GB/T 1804.
- If a drawing or contract cites only ISO 2768, first confirm the referenced part and edition year, then check whether that part covers the dimensional category. Do not apply it to features outside its scope.
- A part number identifies a part of the standard, not a new tolerance class. Record the complete reference and the document specifying the class.
Tolerance decision worksheet
Use this worksheet to identify the requirement for a specific dimension. Record the drawing revision, standard and edition, class and dimensional range, then look up the applicable limit in the specified document.
| Question | Record | Action |
|---|---|---|
| Individual tolerance present? | Dimension ID and explicit limit | Use the applicable specific requirement |
| General note applicable? | Full standard/edition, class and dimensional category/range | Consult the legitimately accessed applicable standard; do not infer the number from this guide |
| No clear note, or notes conflict? | Drawing revision and clarification request | Agree the requirement with the drawing owner before acceptance |
| Result near a limit? | Method, instrument, original reading and specific source clause confirmed by the responsible party | Escalate uncertainty; do not round a failure into a pass |
If drawing notes and contract references conflict, send the exact dimension and conflicting requirements to the responsible drawing or contract owner for clarification before acceptance.
Choosing a class: guidance and pitfalls
- Do not assume class m when a drawing note is missing; check the contract and references before quoting or accepting the dimension.
- The party responsible for design should confirm the class according to function. Tightening an applicable general tolerance may increase manufacturing and inspection cost.
- A coarser class also needs confirmation by the party responsible for design; a supplier must not relax the requirement on its own.
- Use consistent requirements for quotation and inspection. Different bases can lead to acceptance disputes.
- Do not convert GB/T 1804 classes into ISO 2768 classes by assumption; confirm the applicable reference, scope and class.
What to record and check before a decision
- Before measurement, record the drawing and contract revisions, dimension ID, standard part and edition, class, dimensional category/range and source of the applicable limits.
- Check individual tolerances and other specific requirements first: within their scope they take precedence over the general requirement.
- Record the measurement method and condition, instrument and original readings separately. Resolution is one factor in instrument selection; it alone proves neither measurement suitability nor conformity.
- Identify the specific drawing, contract or inspection-procedure clause used for the decision. Use the source confirmed by the responsible party; if the source is unclear, record the requirement as awaiting confirmation rather than inventing a rule.
- For readings near a limit, retain the original record and escalate uncertainty for clarification; do not round a failure into a pass.
For flatness and surface finish measurement methods, see Inspection: flatness and surface finish. Those methods do not establish the tolerance limits for this dimension.
Where to go next
The standards index covers registered records only. For specific general tolerance requirements, check official catalogue metadata, then legitimately obtain the applicable standard cited by the contract. The machine acceptance guide covers documenting machine checks, a separate task from assessing part tolerances.